8 / 0 7 • 1 0 5 1 6 6 A E
Armored Outside Plant Cables
Fiber Optic Cable
Armored Outside Plant Cables
3
w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
Transmission Performance —Guaranteed Minimum Link Lengths
Gigabit Ethernet
Link Length (SX/LX)
10 Gigabit Ethernet
Link Length (SR/LX4)
3
Multimode
62.5/125 µm
300 m/550 m 35 m/300 m
50/125 µm
550 m/550 m 86 m/300 m
50/125 µm Ultra 300
900 m/550 m 300 m/300 m
50/125 µm Ultra 550
1040 m/550 m 550 m/300 m
1
(LR/ER)
Singlemode
NA/5000 m 10 km/40 km
3
10 Gigabit Ethernet distance guarantees at the long wavelength are achieved via four
3.125 Gbps channels multiplexed with WWDM technology
Optical Performance
Maximum Attenuation
(dB/km)
Typical Attenuation
(dB/km)
Bandwidth
1
(MHz/km)
850 nm/1300 nm 850 nm/1300 nm 850 nm/1300 nm
Multimode
62.5/125 µm
3.5/1.5 2.7/0.8 200/500
50/125 µm
3.5/1.5 2.7/0.8 500/500
50/125 µm Ultra 300
3.5/1.5 2.7/0.9 2000/500
2
50/125 µm Ultra 550 3.5/1.5 2.7/0.9 4700
2
/500
1
1310 nm/1550 nm 1310 nm/1550 nm 1310 nm/1550 nm
Singlemode
1.0/1.0 0.4/0.3 N/A
1
Bandwidth measurements specified overfilled launch conditions (OFL)
2
Bandwidth measurements specified by laser launch
Comentários a estes Manuais