MYXPM6021*
Revision 1.1 - 10/21/14
*Advanced information. Subject to change without notice.
30
MYXPM6021*
Form #: CSI-D-685 Document 011
Table7:PMICCurrentConsumption(continued)
Power State Min Typ. [mA] Max
SOC_G3 0.069
G3 0.056
9.4 Voltage Rail Control Mechanism
Properpower-up/downsequencingismandatorytopreventdamages.Thereareseveralmethodscontrollingthepower
rails.
• VCC&VNNarecontrolledviatheSVIDinterface
• Statetransitions,SOCprovidesSLP_S0iX_B,SLP_S3_BandSLP_S4_BsignalstoMYXPM6021controllingthe
relatedpowerrails
• Sequencercontrolling
• Dedicatedregistercontrol
9.5 SVID Interface
SOC communicates with theMYXPM6021 via the SVIDinterface. SVID‘s commands composed of 9bits – 4 MSBs
determinetheaddressand5LSBsarethecommandbits.MYXPM6021supports2SVIDvoltageregulators–VCC&
VNN.Theaddressforeachofthevoltageregulatorisindicatedinthetablebelow:
Table 8: VCC & VNN Addresses
Address Target Description
0x00 VCC All commands will be routed to the VCC SVID registers and MYXPM6021
will
respond with the VCC status information
0x01 VNN All commands will be routed to the VNN SVID registers and MYXPM6021
will
respond with the VNN status information
9.5.1 SVID DC Electrical Parameters
ThefollowingtableoutlinestheSVIDDCelectricalparameters.Notethatlowvoltageoperationisessentialtoavoidlevel
convertersto/fromtheprocessor.MYXPM6021SVIDbuffershouldtakeV1P0S_FBasareferencevoltageforimproved
signalintegrityatthereceiver.