ADC Telecommunications, Inc.
98 CHAPTER 2: CUDA 12000 BASE SYSTEM COMMANDS
cm-filter-default cpe upstream
Specifies the default upstream filter group for CPE devices on all CMTS interfaces.
You can use the cm modify cpe-upstream command to override this default setting on a
modem-by-modem basis.
Mode
Any.
Syntax
cm-filter-default cpe upstream <group-id>
Arguments
Example
cli:root# show cm-filter
row count: 1
Group Index Src Address Src Mask Dest Address Dest Mask
----- ----- ---------------- ---------------- -------------- --------------
1 1 101.100.3.0 255.255.255.0 102.100.3.0 255.255.255.0
cli:root# cm-filter-default cpe upstream 1
cli:root# show cm-filter-default
CPE DS Filter Group 0
CPE US Filter Group 1
CM DS Filter Group 0
CM US Filter Group 0
<group-id> Specifies the ID of a filter group, which you create using the cm-filter
command. The default value is 0, which specifies that no default filter
group is available for upstream filtering. Use the show cm-filter
command to display available filter groups.