ADCP-80-545
Issue 3
March 2006
1361498 Rev A
PowerWorx
®
Power Distribution Products
Select Series Circuit Breaker
Power Distribution Panel User Manual
17943-A
Vista de página 0
1 2 3 4 5 6 ... 35 36

Resumo do Conteúdo

Página 1 - Select Series Circuit Breaker

ADCP-80-545Issue 3March 20061361498 Rev APowerWorx® Power Distribution ProductsSelect Series Circuit BreakerPower Distribution Panel User Manual17943-

Página 2 - DISCLAIMER OF LIABILITY

ADCP-80-545 • Issue 3 • March 2006Page 4© 2006, ADC Telecommunications, Inc.• One set of 23-inch mounting brackets• 5/16-inch long, Phillips drive, 8-

Página 3 - TABLE OF CONTENTS

ADCP-80-545 • Issue 3 • March 2006Page 5© 2006, ADC Telecommunications, Inc.to the panel, the rack, or a location close to the panel. The cards insert

Página 4

ADCP-80-545 • Issue 3 • March 2006Page 6© 2006, ADC Telecommunications, Inc.The circuit breakers are of the type called “short delay.” The trip times

Página 5 - GENERAL SAFETY PRECAUTIONS

ADCP-80-545 • Issue 3 • March 2006Page 7© 2006, ADC Telecommunications, Inc.1.12 Ground ConnectionsTwo #10 studs (with nuts and captive washers) are

Página 6

ADCP-80-545 • Issue 3 • March 2006Page 8© 2006, ADC Telecommunications, Inc.Two breaker alarm indicators (red LED) are provided on the front side of t

Página 7 - 1 PRODUCT DESCRIPTION

ADCP-80-545 • Issue 3 • March 2006Page 9© 2006, ADC Telecommunications, Inc.EnvironmentalOperating temperature –5º C to +55º CStorage temperature –45º

Página 8 - REAR VIEW

ADCP-80-545 • Issue 3 • March 2006Page 10© 2006, ADC Telecommunications, Inc.Figure 3. Dimensions of Select Series Circuit Breaker Panel2 BEFORE START

Página 9 - 1.3 Packaged Hardware

ADCP-80-545 • Issue 3 • March 2006Page 11© 2006, ADC Telecommunications, Inc.connections are made and all tests are completed. Do not apply power to t

Página 10 - 1.5 Accessories

ADCP-80-545 • Issue 3 • March 2006Page 12© 2006, ADC Telecommunications, Inc.• #8–16 AWG insulated copper wire for the output power wires (use black f

Página 11 - 1.8 Circuit Breakers

ADCP-80-545 • Issue 3 • March 2006Page 13© 2006, ADC Telecommunications, Inc.Figure 5. Test 2: Input Battery to Output BatteryTest 3: Input Return to

Página 12 - 1.9 Input/Output Voltage

ADCP-80-545 • Issue 3 • March 2006 • PrefacePage iiCOPYRIGHT© 2006, ADC Telecommunications, Inc.All Rights ReservedPrinted in the U.S.A.REVISION HISTO

Página 13 - 1.14 LED Indicators

ADCP-80-545 • Issue 3 • March 2006Page 14© 2006, ADC Telecommunications, Inc.3.2 Mounting ProcedureThe circuit breaker panel can be mounted in either

Página 14 - 1.16 Specifications

ADCP-80-545 • Issue 3 • March 2006Page 15© 2006, ADC Telecommunications, Inc.Figure 7. Circuit Breaker Panel Mounting Bracket InstallationFigure 8. Ty

Página 15

ADCP-80-545 • Issue 3 • March 2006Page 16© 2006, ADC Telecommunications, Inc.3.3 Chassis Ground ConnectionsMounting the circuit breaker panel on a gro

Página 16

ADCP-80-545 • Issue 3 • March 2006Page 17© 2006, ADC Telecommunications, Inc.Figure 10. Alarm Contact Connections The screw-down type terminal strip

Página 17 - 2.4 Materials Required

ADCP-80-545 • Issue 3 • March 2006Page 18© 2006, ADC Telecommunications, Inc.Figure 11. Output Power Connections3.6 Input Power ConnectionsInput power

Página 18 - 3.1 Test Continuity

ADCP-80-545 • Issue 3 • March 2006Page 19© 2006, ADC Telecommunications, Inc. Use the following procedure to connect the input power cables to the cir

Página 19

ADCP-80-545 • Issue 3 • March 2006Page 20© 2006, ADC Telecommunications, Inc.Figure 13. Input Power Connections3.7 Protective Cover Installation/Remov

Página 20 - 3.2 Mounting Procedure

ADCP-80-545 • Issue 3 • March 2006Page 21© 2006, ADC Telecommunications, Inc.To provide access to the input and output power terminals, it may sometim

Página 21

ADCP-80-545 • Issue 3 • March 2006Page 22© 2006, ADC Telecommunications, Inc.Figure 16. Circuit Designation Card and Voltage Label4 TESTINGFollowing i

Página 22

ADCP-80-545 • Issue 3 • March 2006Page 23© 2006, ADC Telecommunications, Inc.5 OPERATIONOperation of the Select Series circuit breaker panel consists

Página 23 - 3.5 Output Power Connections

ADCP-80-545 • Issue 3 • March 2006 • PrefacePage iii© 2006, ADC Telecommunications, Inc.TABLE OF CONTENTSContent PageABOUT THIS MANUAL . . . . . . .

Página 24 - 3.6 Input Power Connections

ADCP-80-545 • Issue 3 • March 2006Page 24© 2006, ADC Telecommunications, Inc.1. Remove the plastic protective covers from the rear side of the output

Página 25

ADCP-80-545 • Issue 3 • March 2006Page 25© 2006, ADC Telecommunications, Inc.2. Use a needle-nose pliers to disconnect the lead wire terminals (quick-

Página 26

ADCP-80-545 • Issue 3 • March 2006Page 26© 2006, ADC Telecommunications, Inc.Figure 18. Releasing Circuit Breaker Lock Tab2. Insert a flat-bladed scr

Página 27

ADCP-80-545 • Issue 3 • March 2006Page 27Figure 19. Single-Pole Circuit Breaker Wiring ConnectionsFigure 20. Two-Pole Circuit Breaker Wiring Connecti

Página 28 - VOLTAGE LABEL

ADCP-80-545 • Issue 3 • March 2006Page 28© 2006, ADC Telecommunications, Inc.7 CUSTOMER INFORMATION AND ASSISTANCE© 2006, ADC Telecommunications, Inc.

Página 31 - Figure 17. LED Indicator

ADCP-80-545 • Issue 3 • March 2006 • PrefacePage iv© 2006, ADC Telecommunications, Inc.TABLE OF CONTENTSContent Page5.1 Circuit Breaker Operation. . .

Página 32 - 2.TILT BREAKER FORWARD

ADCP-80-545 • Issue 3 • March 2006 • PrefacePage v© 2006, ADC Telecommunications, Inc.ABOUT THIS MANUALThis manual describes the PowerWorx Select Seri

Página 33 - FRONT VIEW

ADCP-80-545 • Issue 3 • March 2006 • PrefacePage vi© 2006, ADC Telecommunications, Inc.Caution: Using the wrong circuit breaker may cause damage to th

Página 34 - Italy: 0800 782374

ADCP-80-545 • Issue 3 • March 2006Page 1© 2006, ADC Telecommunications, Inc.1 PRODUCT DESCRIPTIONThis section describes the functions and features pro

Página 35

ADCP-80-545 • Issue 3 • March 2006Page 2© 2006, ADC Telecommunications, Inc.Figure 1. Select Series Circuit Breaker Panel (Typical)BUS APOWER-ONINDICA

Página 36

ADCP-80-545 • Issue 3 • March 2006Page 3© 2006, ADC Telecommunications, Inc.The input power terminals, output power terminals, alarm terminals, and gr