ADC Soneplex P-61-743 Especificações Página 19

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 18
- 18 -
Controller
input power
supply
Controller
input power
supply
Controller
input power
supply
(4) Stop the power supply for the motor
If it is necessary to shut off the power supply for the motor from outside, connect the relay between the
input power supply for the controller 24VDC and the power supply plug for the controller M24V.
Warning
Do not perform returning to origin position neither drive operation when the the power supply
for the motor (M24V) is shut off, otherwise alarm will be generated.
The controller does not recognize the correct origin position with the command for returning to
the origin position at the time of the shutoff of the power supply for the motor (M24V).
1st ptoduct
Example of the circuit
24VDC
Ry
0V
STOP
switch
Surge suppresso
r
Reset switch for stop
Ry
Ry
Controlle
r
0V
M24V
C24V
BK RLS
24V
0V
Ry
Controlle
r
24V
0V
Ry
Controlle
r
24V
0V
3rd ptoduct
0V
M24V
C24V
BK RLS
2nd ptoduct
0V
M24V
C24V
BK RLS
Vista de página 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 78 79

Comentários a estes Manuais

Sem comentários