- 38 -
7.4 Test function
The table below shows the difference between normal operation and test function in manual mode. To
start the test function, set the position switch
h to "0" while the power LED
a is on (= servo ON)
in manual mode and the actuator stops, and press the set button
g for 3sec. When test function
starts, the dot on the lower right of the 7-segment LED
f will light up.
Normal operation Test function
Availability of
pushing operation
X O
Operation by parallel
I/O input
X X
Output to parallel I/O X O
7-segment LED
f
display
Without dot
Target position setting:
Quick flashing
During operation: Slow
flashing
Reached the target position:
Lights up
With dot
Target position setting: Quick
flashing
During operation: Slow
flashing
Reached the target position:
Lights up
Adjustment of the
speed / acceleration
O O
Operation method
using buttons
Moves towards the target
position only while the set
button
g is pressed.
Moves towards the target
position when the set
button
g is pressed. (Not
necessary to keep pressing
the button)
e
j
i
c
k
m
l
n
g
h
f
a