Error messages Description of error Error clearance
LINE INT. Power failure Note: Cancel error in RESET-QUIT menu
no counting during power failure Reset totalizer if necessary.
OVERFLOW I Current output overranged. Check and if necessary correct
instrument parameters. After
elimination of cause, error message
deleted automatically.
OVERFLOW P Pulse output overranged. Check and if necessary correct
Note: instrument parameters. After
totalizer deviation possible. elimination of cause, error message
deleted automatically.
TOTALIZER Totalizer has been reset Cancel error message in
RESET/QUIT. menu.
ADC Analog / digital Error message deleted automatically
converter overranged after elimination of cause.
FATAL. ERROR Fatal error, all outputs set Please consult factory.
to “min. values”
EMPTY PIPE Pipe has run dry. Fill pipe.
This message appears only when
the “empty pipe identifier”
option is installed and the function
is switched on under Fct. 3.06
APPLICAT., submenue
“EMPTY PIPE”.
Error messages in measuring mode 4.5
The following list gives all errors that can occur during process flow measurement.
Errors shown in display when “YES” set in Fct. 1.04 DISPLAY, subfunction “DISP. MSG.”: