Table 11: AMI HDSL Span - Provisioning
Required Tests General Information Parameters
Pulse (Attenuation) HDSL reading at customer
premises (This reading is taken
once there is continuity between
the 2 HDSL units and HDSL sync
has been acquired)
Retrieve reading via menu
software.
ADC/Pairgain
0 to -28 dB
(Each link when doublers are used.)
Adtran HDSL and HDSL2
0 to -30 dB
(Each link when doublers are used.)
Adtran HDSL4
0 to -35 dB (No regenerator or 1st link ( CO to regenerat-
or))
0 to -31 dB (Regenerated signal 2nd link (regenerator to
premise.))
Signal to Noise
Signal Quality
Margin
HDSL reading at customer
premises (This reading is taken
once there is continuity between
the two HDSL units and HDSL
sync has been acquired)
Retrieve reading via menu
software.
ADC/Pairgain or Adtran(HDSL, HDSL2 or HDSL4)
6 or greater
Signal Level HDSL card reading at customer
premises
Measure 1.544 signal at drop
side of HDSL card (RJ48C)
ADC/Pairgain or Adtran
0 to -7.5 DB
Note: 0 DB level may be as high as +1.6 DB
QRSS
1 five minute test
test pattern 0 errors
3 in 24
1 two minute test
test pattern 0 errors
All Ones
1 two minute test
test pattern 0 errors
On All HDSL Cards:
AT&T Practice ATT-TP-000-000-006
Issue 1, 08/25/06