Table 17: AMI HDSL Span - Maintenance
Required Tests General Information Parameters
Pulse (Attenuation) HDSL card reading at customer
premises
ADC/Pairgain
0 to -28 DB
(Each link when doublers are used.)
Adtran HDSL and HDSL2
0 to -30 DB
(Each link when doublers are used.)
Adtran HDSL4
0 to -35 dB (No regenerator or 1st link ( CO to regenerator))
0 to -31 dB (Regenerated signal 2nd link (regenerator to
premise.))
Signal to Noise Margin HDSL card reading at customer
premises
ADC/Pairgain or Adtran
6 or greater
Signal Level HDSL card reading at customer
premises
ADC/Pairgain or Adtran
0 to -7.5 DB
Note: 0 DB level may be as high as +1.6 DB
QRSS
1 five minute test
test pattern 0 errors
3 in 24
1 two minute test
test pattern 0 errors
All Ones
1 two minute test
test pattern 0 errors
On HDSL Cards:
Date and time must be set.
Actual pair loss should not exceed -35 dB at 196 kHz using a 135 # termination per link or section. This is not a
AT&T Practice ATT-TP-000-000-006